Zerodraft foam sealant seals gaps and cracks in walls, roof-wall connections,
the perimeter of doors and window openings, mechanical and electrical penetrations
and similar locations to provide a continuous, impermeable barrier to air infiltration
or loss.
Uses -Zerodraft foam sealant:
• is intended to be installed at junctions to seal between different building
elements and around penetrations in a building assembly.
• is dispensed as a bead or crack gap filling. A crack being less than
6mm (1/4 in) wide and a gap being less than 50mm (2in) wide.
• can be trimmed and painted where appearance is an issue.
Limitations:
Do not use Zerodraft foam sealants:
• Where it is subject to continuous service temperatures are outside the
range of -60°C to +80°C such as in contact with chimneys, heater vents,
steam pipes, etc. unless the sealant has been designed for use and other service
temperature as specified by Zero Draft.
• On or in the vicinity of heat emitting devices such as recessed lighting
fixtures, at a lesser distance than 75 mm (3 “) or as specified by the
authority having jurisdiction.
• Inside electrical outlets or junction boxes.
• Left exposed to continuous ultra violet light.
• Immersed in water for long periods of time.
Features
• High yield; a standard 24 oz can will produce 280
linear meters of 13mm diameter bead.
• Quick cure; tack free in 8 minutes and cut through in 45 minutes (50%
relative humidity).
• Fire retardant; self extinguishing in absent of flame produces flame
spread rating of less than 25 and smoke develop rating of less than 50 when tested
to CAN/ULC-S102 and ASTM E-84 in a range of bead sizes. (not a fire stop; see
Zerodraft Air Seal/Fire Stop Systems literature)
• Safe formula; does not contain urea formaldehyde, CFC’s, chlorofluorocarbons
or solvents.
• Excellent insulating properties; 70% closed cell content provides RSI
value of 0.961 per 305 mm thickness (R Value of 5.4 per 1” thickness).
Standards Conformance
• CAN/ULC-S710.1 Standard For Thermal Insulation – Bead
Applied One-Component Polyurethane Air Sealant Foam, Part 1: Material Specification.
• CAN/ULC-S710.2 Standard For Thermal Insulation – Bead Applied One-Component
Polyurethane Air Sealant Foam, Part 2: Application.
• CCMC 09552 Product Evaluation (Canadian Construction Materials Center,
NRC).
Building Codes
Zerodraft Foam Sealant complies with the following Sections
of the National Building Codes:
• 3.1.5.2 Minor Combustible Components (Zerodraft Foam
Sealant is permitted in buildings required to be of non-combustible construction).
• 5.4.1.2 Air Barrier System Properties (Zerodraft Foam Sealant falls within
the maximum allowable air leakage rated of 0.02 l/s-m sq.) measured at an air
pressure difference of 75 Pa.
• A-6.4.1.2 (1) and (2) Air Leakage Through The Air Barrier System (Zerodraft
Foam Sealant falls within the recommended maximum allowable leakage rates as
related to warm and cold side temperatures and humidity conditions.
• Health/Safety: A material Safety Data Sheet is provided with every case
of Zerodraft Foam Sealant. Instructions for the safe handling, use and disposal
of the materials and/or containers is provided on the label of each container.
• Packaging: 24 oz. (682 m) container, 12 containers per case.
• Warranty: Normal 1 year construction warranty.
Installation:
• Storage/Shelf Life: Do not expose to heat or store
above 50?C. Do not leave in vehicle. Shelf life is 18 months.
• Surface Preparation: Apply to clean substrates free of oil, grease or
excessive moisture.
• Application: Zerodraft Foam Sealant should be applied only by accredited
Zerodraft applicators.
Technical Data
|